High-density polyethylene reducers used in: – Domestic sewage (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems inside high-rise buildings, public buildings, industrial halls. – Ventilation columns for sewage systems. – Domestic sewage (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems installed buried in the ground – range of PE100 pipes and fittings – SDR26 (S12.5) – Vacuum stormwater drainage, made of welded PE100 pipes and fittings (electro)welded. Characteristics – Diameter range: (fi)32, (fi)40, (fi)50, (fi)56, (fi)63, (fi)75, (fi)90, (fi)110, (fi)125, (fi)160, (fi)200, (fi)250. (Ø)315. – Compliance: EN 1519. – Series: S12.5 for SDR26 and S16 for SDR33. – Application classes: – B – for use inside and outside buildings, wall-anchored. – BD – for use inside buildings or buried in the ground within the building perimeter (at a maximum distance of 1 m from it and connected to the building’s drainage system). For this use, only pipes with diameters of 75 mm or larger belonging to the S12.5 series are permitted. – Material: high-density polyethylene. – Type: single-layer. – Maximum operating temperature: +95°C, intermittent. – Color: black. – Joining methods: – Butt fusion and electrofusion coupling: PE100 SDR26 at 5 bar/−800 mbar and PE100 SDR33 at 4 bar/−450 mbar, with fluid at +20°C and safety factor 1.25. – Socket and gasket joint, expansion sleeve – max. 0.5 bar. – Mechanical flanged joint. – Mechanical joint with threaded fittings.
LONG INJECTED HDPE OFFSET REDUCER VALRain D.160/125
High-density polyethylene reducers used in: - Domestic sewage (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems inside high-rise buildings, public buildings, industrial halls. - Ventilation columns for sewage systems. – Domestic sewage systems (intermittent +95°C, continuous +80°C) and gravitational rainwater systems installed underground – PE100 pipes and fittings range – SDR26 (S12.5) – Vacuum rainwater drainage, made from (electro)welded PE100 pipes and fittings. Characteristics – Diameter range: DN32, DN40, DN50, DN56, DN63, DN75, DN90, DN110, DN125, DN160, DN200, DN250. DN315. – Compliance: EN 1519. – Series: S12.5 for SDR26 and S16 for SDR33. – Application classes: – B – intended for use inside and outside buildings, anchored to the wall. – BD – intended for use inside buildings or buried underground within the building perimeter (at a maximum distance of 1 m from it and connected to the building's drainage system). For this application, only pipes with diameters equal to or greater than 75 mm belonging to the S12.5 series are permitted. – Material: High-density polyethylene. – Type: Monolayer – Maximum operating temperature: +95°C, intermittently. – Color: Black – Joining methods: – Butt welding and electrofusion socket welding: PE100 SDR26 for 5 bar/-800 mbar and for PE100 SDR33 for 4 bar/-450 mbar under fluid conditions at +20°C and a safety factor of 1.25. – Socket and gasket joint, expansion sleeve – maximum 0.5 bar. – Mechanical flange joint. – Mechanical joint with threaded fittings.
| UM colete | BOX |
|---|---|
| Tip articol | REDUCTIONS |
| Material | HDPE |
| Cod CPV | CPV 44160000-9 |
| Cantitate colet | 5 |
| Diametru | 160/125 |
| Cod vamal | 39174000 |
| Subclasa | STORMWATER DRAINAGE FITTINGS |