High-density polyethylene reducers used in: – Domestic sewage (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems inside high-rise buildings, public buildings, industrial halls. – Ventilation columns for sewage systems. – Domestic sewage (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems installed buried in the ground – range of PE100 pipes and fittings – SDR26 (S12.5) – Vacuum stormwater drainage, made of welded PE100 pipes and fittings (electro)welded. Characteristics – Diameter range: (fi)32, (fi)40, (fi)50, (fi)56, (fi)63, (fi)75, (fi)90, (fi)110, (fi)125, (fi)160, (fi)200, (fi)250. (Ø)315. – Compliance: EN 1519. – Series: S12.5 for SDR26 and S16 for SDR33. – Application classes: – B – for use inside and outside buildings, wall-anchored. – BD – for use inside buildings or buried in the ground within the building perimeter (at a maximum distance of 1 m from it and connected to the building’s drainage system). For this use, only pipes with diameters of 75 mm or larger belonging to the S12.5 series are permitted. – Material: high-density polyethylene. – Type: single-layer. – Maximum operating temperature: +95°C, intermittent. – Color: black. – Joining methods: – Butt fusion and electrofusion coupling: PE100 SDR26 at 5 bar/−800 mbar and PE100 SDR33 at 4 bar/−450 mbar, with fluid at +20°C and safety factor 1.25. – Socket and gasket joint, expansion sleeve – max. 0.5 bar. – Mechanical flanged joint. – Mechanical joint with threaded fittings.
SHORT ECCENTRIC REDUCER VALRain HDPE D. 75/56
High-density polyethylene reducers used in: - Domestic sewage (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems inside high-rise buildings, public buildings, industrial halls. - Ventilation columns for sewage systems. - Domestic sewage (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems installed buried in the ground - range of PE100 pipes and fittings - SDR26 (S12.5) - Vacuum stormwater drainage, made of welded PE100 pipes and fittings (electro)welded. Characteristics - Diameter range: (fi)32, (fi)40, (fi)50, (fi)56, (fi)63, (fi)75, (fi)90, (fi)110, (fi)125, (fi)160, (fi)200, (fi)250, (fi)315. - Compliance: EN 1519. - Series: S12.5 for SDR26 and S16 for SDR33. - Application classes: - B - intended for use inside and outside buildings, wall-mounted. - BD - intended for use inside buildings or buried in the ground within the building perimeter (at a maximum distance of 1 m from it and connected to the building's sewage system). For this use, only pipes with diameters equal to or greater than 75 mm belonging to series S12.5 are permitted. - Material: high-density polyethylene. - Type: single-layer - Maximum operating temperature: +95°C, intermittent. - Color: black - Joining methods: - Butt welding and electrofusion socket: PE100 SDR26 of 5 bar/-800 mbar and for PE100 SDR33 of 4 bar/-450 mbar under fluid conditions at +20°C and safety factor 1.25. - Socket and gasket joint, expansion coupling - maximum 0.5 bar. - Mechanical flange joint. - Mechanical joint with threaded fittings.
| UM colete | BOX |
|---|---|
| Tip articol | REDUCTIONS |
| Material | HDPE |
| Cod CPV | CPV 44160000-9 |
| Cantitate colet | 30 |
| Diametru | 75/56 |
| Cod vamal | 39174000 |
| Subclasa | STORMWATER DRAINAGE FITTINGS |




