For cold and hot water plumbing installations, respectively
in heating installations, as follows:
– Class 1 (hot water 60°C) – design temperature for service
life: 60°C/49 years + 80°C/1 year + 95°C/100 hours.
– Class 2 (hot water 70°C) – design temperature for service
life: 70°C/49 years + 80°C/1 year + 95°C/100 hours.
– Class 5 (radiator heating) – design temperature for service
life: 80°C/10 years + 60°C/25 years + 20°C/14
years + 90°C/1 year +100°C/100 hours.
VALDuotherm GRAY PPR/FIBER PIPE Ø 20×3.4mm SDR6 L 3m
The VALDuotherm PP-R/PP-R+GF/PP-R SDR 6 pipe is utilized for indoor installations for cold water supply, hot water, and heating, as follows:
- Class 1 - hot water 60°C – PN 10 bar; design temperature for service life: 60°C/49 years + 80°C/1 year + 95°C/100 hours;
- Class 2 (hot water 70°C) - PN 8 bar; design temperature for service life: 70°C/49 years + 80°C/1 year + 95°C/100 hours;
- Class 5 (heating installations including high-temperature radiators) - PN 6 bar, design temperature for service life: 20°C/14 years + 60°C/25 years + 80°C/10 years + 90°C/1 year +100°C/100 hours;
- Cold water PN 20 bar at c =1.5 and PN 25 bar at c=1.25 (Informative - In accordance with SR EN ISO 21003-1 - the design pressure for domestic cold water installations for a period of 50 years at a temperature of 20 °C is 10 bar).
Reference Standard: SR EN ISO 21003-2 - Multilayer piping systems for hot and cold water installations inside buildings, Part 2: Pipes
The linear expansion coefficient of PP-R/PP-R+GF/PP-R pipes is α = 0.045 mm/m K, which is why the effect of pipe expansion or contraction must be evaluated before wall mounting (surface mounting) of PP-R/PP-R+GF/PP-R pipes. Correct installation of clamps or other support types and proper positioning of expansion compensators prevent uncontrolled pipe movement due to temperature variations during installation and operation. As a rule, installation expansion is compensated between 2 fixed points by changing direction, using an expansion loop, or where not possible, compensators must be fixed between the pipe and the structure. Fixing clamps (also called fixed points) of the installation are positioned near branches, valves, or wall penetrations, while sliding clamps are mounted along the installation route at well-defined distances. This ensures installation alignment, support, and controlled axial movement. When installing fiber-reinforced PP-R pipes in screed or walls, they must be placed in protective tubes with a flexible, well-insulating structure capable of absorbing pipe expansion. In case of excessive expansion that is difficult to compensate with the insulating protective tube, an expansion compensator must be calculated and installed. Please note, pipes must be installed at an acceptable depth under the screed or inside the wall to avoid cracks; additionally, excessive internal stresses at joints must be avoided. The installation depth must be greater than or equal to 1.5 × the outer diameter of the tube. Threaded joints are not permitted in screed or walls. The pressure test is performed before the final burial of the tube/installation.
The technical manual addresses methods for evaluating expansion and ways to compensate for it, including clamp positioning.
- Class 1 - hot water 60°C – PN 10 bar; design temperature for service life: 60°C/49 years + 80°C/1 year + 95°C/100 hours;
- Class 2 (hot water 70°C) - PN 8 bar; design temperature for service life: 70°C/49 years + 80°C/1 year + 95°C/100 hours;
- Class 5 (heating installations including high-temperature radiators) - PN 6 bar, design temperature for service life: 20°C/14 years + 60°C/25 years + 80°C/10 years + 90°C/1 year +100°C/100 hours;
- Cold water PN 20 bar at c =1.5 and PN 25 bar at c=1.25 (Informative - In accordance with SR EN ISO 21003-1 - the design pressure for domestic cold water installations for a period of 50 years at a temperature of 20 °C is 10 bar).
Reference Standard: SR EN ISO 21003-2 - Multilayer piping systems for hot and cold water installations inside buildings, Part 2: Pipes
The linear expansion coefficient of PP-R/PP-R+GF/PP-R pipes is α = 0.045 mm/m K, which is why the effect of pipe expansion or contraction must be evaluated before wall mounting (surface mounting) of PP-R/PP-R+GF/PP-R pipes. Correct installation of clamps or other support types and proper positioning of expansion compensators prevent uncontrolled pipe movement due to temperature variations during installation and operation. As a rule, installation expansion is compensated between 2 fixed points by changing direction, using an expansion loop, or where not possible, compensators must be fixed between the pipe and the structure. Fixing clamps (also called fixed points) of the installation are positioned near branches, valves, or wall penetrations, while sliding clamps are mounted along the installation route at well-defined distances. This ensures installation alignment, support, and controlled axial movement. When installing fiber-reinforced PP-R pipes in screed or walls, they must be placed in protective tubes with a flexible, well-insulating structure capable of absorbing pipe expansion. In case of excessive expansion that is difficult to compensate with the insulating protective tube, an expansion compensator must be calculated and installed. Please note, pipes must be installed at an acceptable depth under the screed or inside the wall to avoid cracks; additionally, excessive internal stresses at joints must be avoided. The installation depth must be greater than or equal to 1.5 × the outer diameter of the tube. Threaded joints are not permitted in screed or walls. The pressure test is performed before the final burial of the tube/installation.
The technical manual addresses methods for evaluating expansion and ways to compensate for it, including clamp positioning.
| Ambalare | PLASTIC BAG |
|---|---|
| Culoare | GRI |
| Material | PPR |
| Tip articol | TEAVA |
| UM colete | BAG |
| Tara origine preferentiala | EU |
| Cod CPV | CPV 44115200-1 |
| Lungime | 3 m |
| SDR | 6 |
| Diametru | 20 |
| Cantitate colet | 20 |
| Diametru(mm) | |
| Durata estimata de viata | 50 Years |
| Perioada garantie | 60 Months |
| Cod vamal | 39172210 |
| Subclasa | PRESSURE PIPES PPR GRAY WITH FIBER |




