Used in: – Domestic wastewater drainage systems (intermittent +95°C, continuous +80°C) and gravity stormwater drainage inside high-rise buildings, public buildings, industrial halls. – Vent stacks for drainage systems. – Domestic wastewater drainage systems (intermittent +95°C, continuous +80°C) and gravity stormwater drainage installed buried in the ground – range of PE100 pipes and fittings – SDR26 (S12.5)
Features
– Diameter range: (Ø)32, (Ø)40, (Ø)50, (Ø)56, (Ø)63, (Ø)75, (Ø)90, (Ø)110, (Ø)125, (Ø)160, (Ø)200, (Ø)250, (Ø)315.
– Compliance: EN 1519.
– Series: S12.5 for SDR26 and S16 for SDR33.
– Application classes:
– B – intended for use inside and outside buildings, wall-anchored.
– BD – intended for use inside buildings or buried in the ground within the building perimeter (at a maximum distance of 1 m from it and connected to the building’s drainage system). For this use, only pipes with diameters of 75 mm or larger belonging to series S12.5 are permitted.
– Material: high-density polyethylene.
– Type: single-layer
– Maximum operating temperature: +95°C, intermittent.
– Color: black
– SafeKit system joining methods:
– Butt fusion and electrofusion coupling: PE100 SDR26 at 5 bar/-800 mbar and PE100 SDR33 at 4 bar/-450 mbar, with fluid at +20°C and safety factor 1.25.
– Socket-and-gasket joint, expansion sleeve – max. 0.5 bar.
– Mechanical flanged joint.
– Mechanical joint with threaded fittings.
VALRain HDPE D.315 SOCKET CONNECTOR WITHOUT CAP
Used in: - Domestic wastewater drainage systems (intermittent +95°C, continuous +80°C) and gravity stormwater drainage inside high-rise buildings, public buildings, industrial halls. - Vent stacks for drainage systems. - Domestic wastewater drainage systems (intermittent +95°C, continuous +80°C) and gravity stormwater drainage installed buried in the ground - range of PE100 pipes and fittings - SDR26 (S12.5)
Features
- Diameter range: (Ø)32, (Ø)40, (Ø)50, (Ø)56, (Ø)63, (Ø)75, (Ø)90, (Ø)110, (Ø)125, (Ø)160, (Ø)200, (Ø)250, (Ø)315.
- Compliance: EN 1519.
- Series: S12.5 for SDR26 and S16 for SDR33.
- Application classes:
- B - intended for use inside and outside buildings, wall-anchored.
- BD - intended for use inside buildings or buried in the ground within the building perimeter (at a maximum distance of 1 m from it and connected to the building’s drainage system). For this use, only pipes with diameters of 75 mm or larger belonging to series S12.5 are permitted.
- Material: high-density polyethylene.
- Type: single-layer
- Maximum operating temperature: +95°C, intermittent.
- Color: black
- SafeKit system joining methods:
- Butt fusion and electrofusion coupling: PE100 SDR26 at 5 bar/-800 mbar and PE100 SDR33 at 4 bar/-450 mbar, with fluid at +20°C and safety factor 1.25.
- Socket-and-gasket joint, expansion sleeve - max. 0.5 bar.
- Mechanical flanged joint.
- Mechanical joint with threaded fittings.
| UM colete | PIECE |
|---|---|
| Tip articol | CONNECTOR |
| Material | HDPE |
| Cod CPV | CPV 44167300-1 |
| Cantitate colet | 1 |
| Diametru | 315 |
| Cod vamal | 39174000 |
| Subclasa | STORMWATER DRAINAGE FITTINGS |