High-density polyethylene branches used in: – Domestic sewage systems (intermittent +95°C, continuous +80°C) and gravitational rainwater systems inside high-rise buildings, public buildings, industrial halls. – Ventilation columns for sewage systems. – Domestic sewage systems (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems installed underground – PE100 pipe and fitting range – SDR26 (S12.5). – Vacuum stormwater drainage, made from (electro)welded PE100 pipes and fittings. Characteristics: – Diameter range: Ø32, Ø40, Ø50, Ø56, Ø63, Ø75, Ø90, Ø110, Ø125, Ø160, Ø200, Ø250, Ø315. – Compliance: EN 1519. – Series: S12.5 for SDR26 and S16 for SDR33. – Application classes: – B – intended for use inside and outside buildings, wall-anchored. – BD – intended for use inside buildings or buried underground within the building’s perimeter (at a maximum distance of 1 m from it and connected to the building’s sewage system). For this application, only pipes with diameters equal to or greater than 75 mm belonging to the S12.5 series are permitted. – Material: High-density polyethylene. – Type: Monolayer. – Maximum operating temperature: +95°C, intermittently. – Color: Black. – Joining methods: – Butt welding and electrofusion socket: PE100 SDR26 for 5 bar/-800 mbar and for PE100 SDR33 for 4 bar/-450 mbar under fluid conditions at +20°C and a safety factor of 1.25. – Socket and gasket joint, expansion sleeve – maximum 0.5 bar. – Mechanical flange joint. – Mechanical joint with threaded fittings.
VALRain Injected HDPE Reducing Branch, 88°30′, D. 75/56
High-density polyethylene branches used in: - Domestic sewage systems (intermittent +95°C, continuous +80°C) and gravitational rainwater systems inside high-rise buildings, public buildings, industrial halls. - Ventilation columns for sewage systems. Applications: - Domestic sewage systems (intermittent +95°C, continuous +80°C) and gravity stormwater drainage systems installed underground - PE100 pipe and fitting range - SDR26 (S12.5). - Vacuum stormwater drainage, made from (electro)welded PE100 pipes and fittings. Characteristics: - Diameter range: Ø32, Ø40, Ø50, Ø56, Ø63, Ø75, Ø90, Ø110, Ø125, Ø160, Ø200, Ø250, Ø315. - Compliance: EN 1519. - Series: S12.5 for SDR26 and S16 for SDR33. - Application classes: - B - intended for use inside and outside buildings, wall-anchored. - BD - intended for use inside buildings or buried underground within the building's perimeter (at a maximum distance of 1 m from it and connected to the building's sewage system). For this application, only pipes with diameters equal to or greater than 75 mm belonging to the S12.5 series are permitted. - Material: High-density polyethylene. - Type: Monolayer. - Maximum operating temperature: +95°C, intermittently. - Color: Black. - Joining methods: - Butt welding and electrofusion socket: PE100 SDR26 for 5 bar/-800 mbar and for PE100 SDR33 for 4 bar/-450 mbar under fluid conditions at +20°C and a safety factor of 1.25. - Socket and gasket joint, expansion sleeve - maximum 0.5 bar. - Mechanical flange joint. - Mechanical joint with threaded fittings.
| UM colete | BOX |
|---|---|
| Tip articol | REMARIFICATIONS |
| Material | HDPE |
| Cod CPV | CPV 44160000-9 |
| Cantitate colet | 20 |
| Diametru | 75/56 |
| Unghi | 88 Degrees |
| Cod vamal | 39174000 |
| Subclasa | STORMWATER DRAINAGE FITTINGS |