FONO BF PIPE D160 1 SOCKET L1000
Used in indoor sewer installations for discharging domestic wastewater in gravity flow without pressure (where the leak-tightness test is carried out at max. 0.5 bar), especially for building stacks, where sound damping from water discharge from upper floors is desired.
Reference standard: EN 1451.
The pipes, black in color, are made of PP with mineral additives, with a triple-layer wall construction, fitted at one end with a socket and gasket.
The size range includes diameters from 32 mm to 160 mm, with lengths between 250 and 3000 mm.
Acoustic performance is 16 dB at a flow rate of 2 l/s. The sound-absorbing properties are certified based on measurements carried out in the laboratories of the Fraunhofer Institute in Germany, in accordance with EN 14366. The use of sound-absorbing clamps is recommended.
The fire behavior classification of the piping in accordance with DIN 4102-1 is rated as class B1. When passing through ceilings, we recommend using fire collars as a flame-spread protection measure.
To reduce the noise level of indoor sewer systems, the following is recommended:
• Choose a pipe and fitting system with good sound-absorbing properties;
• Ensure correct system design;
• Install the system correctly using suitable products.
Reference standard: EN 1451.
The pipes, black in color, are made of PP with mineral additives, with a triple-layer wall construction, fitted at one end with a socket and gasket.
The size range includes diameters from 32 mm to 160 mm, with lengths between 250 and 3000 mm.
Acoustic performance is 16 dB at a flow rate of 2 l/s. The sound-absorbing properties are certified based on measurements carried out in the laboratories of the Fraunhofer Institute in Germany, in accordance with EN 14366. The use of sound-absorbing clamps is recommended.
The fire behavior classification of the piping in accordance with DIN 4102-1 is rated as class B1. When passing through ceilings, we recommend using fire collars as a flame-spread protection measure.
To reduce the noise level of indoor sewer systems, the following is recommended:
• Choose a pipe and fitting system with good sound-absorbing properties;
• Ensure correct system design;
• Install the system correctly using suitable products.
| Material | PP |
|---|---|
| Tip articol | TUB |
| UM colete | BOX |
| Cod CPV | CPV 44163130-0 |
| Lungime | 1 m |
| Cantitate colet | 6 |
| Diametru | 160 |
| Diametru(mm) | |
| Cod vamal | 39172210 |
| Subclasa | SOUND-ABSORBING PP PIPES |