4SILENCE Acoustic PVC Pipe D.200×4.9 L2000
This pipe is utilized in internal drainage systems for the gravity flow discharge of domestic wastewater (where the leak test is conducted at a maximum of 0.5 bar). It is particularly suited for building risers where sound attenuation from water discharge from upper floors is desired.
Reference Standard: SR EN 1329-1.
The white pipes are manufactured by co-extrusion from PVC-U with mineral additives, featuring a triple-layer wall construction, and are equipped with a socket and gasket at one end.
The size range includes diameters from 50 mm to 200 mm, with lengths between 250 mm and 3000 mm.
Acoustic performance is 11 dB for a flow rate of 2 L/s. The sound-absorbing properties are certified following measurements conducted at the Fraunhofer Institute laboratories in Germany, in accordance with EN 14366. The use of sound-absorbing clamps is recommended.
The fire behavior classification of the piping, in accordance with SR EN 13501, falls under class C – s3 – d0. The material is fire-resistant and self-extinguishing once the fire source is removed. Unlike other internal drainage materials, PVC-U is inherently flame-retardant, eliminating the need for additional fireproofing. When passing through ceilings, we recommend using fire collars as a protective measure against flame propagation.
To reduce the noise level of internal drainage systems, we recommend:
• Selecting a pipe and fitting system with good sound-absorbing properties;
• Ensuring correct system design;
• Installing the system correctly using appropriate products.
Reference Standard: SR EN 1329-1.
The white pipes are manufactured by co-extrusion from PVC-U with mineral additives, featuring a triple-layer wall construction, and are equipped with a socket and gasket at one end.
The size range includes diameters from 50 mm to 200 mm, with lengths between 250 mm and 3000 mm.
Acoustic performance is 11 dB for a flow rate of 2 L/s. The sound-absorbing properties are certified following measurements conducted at the Fraunhofer Institute laboratories in Germany, in accordance with EN 14366. The use of sound-absorbing clamps is recommended.
The fire behavior classification of the piping, in accordance with SR EN 13501, falls under class C – s3 – d0. The material is fire-resistant and self-extinguishing once the fire source is removed. Unlike other internal drainage materials, PVC-U is inherently flame-retardant, eliminating the need for additional fireproofing. When passing through ceilings, we recommend using fire collars as a protective measure against flame propagation.
To reduce the noise level of internal drainage systems, we recommend:
• Selecting a pipe and fitting system with good sound-absorbing properties;
• Ensuring correct system design;
• Installing the system correctly using appropriate products.
| Tip articol | TUB |
|---|---|
| UM colete | BOX |
| Material | PVC |
| Fanta | 0 mm |
| Unghi | 0 Grade |
| Cod CPV | CPV 44163130-0 |
| Lungime | 2 m |
| Cantitate colet | 9 |
| Diametru | 200 |
| Cod vamal | 39172310 |
| Subclasa | 4SILENCE PVC Drainage Pipes |