This manifold is used in underfloor heating/cooling systems and for radiator heating. It distributes the heating agent to the underfloor heating coils and radiators, as well as the chilled agent for underfloor cooling. Includes: – 1 manifold bar with flow meters. – 1 manifold bar with thermostatic valves – electric control option (thermoelectric head/actuator) – 2 manual air vents – 2 drain valves – 2 end caps 1″ – 2 manifold supports. The balancing valve (detentor) is a balancing valve for flow and pressure drop according to project specifications. For flow visualization in underfloor heating, a PexKIT 3/4″ flow meter (0.5-2.4 L/MIN) Valrom Code 64199000025 can be installed on the return (manifold with thermostatic valves) for each circuit. Manufacturing standard: UNI EN ISO 9001:2015 Certification. Manifold body: AISI 304 Stainless Steel. Thread: ISO 228/1. Max. temperature: 100°C. Max. pressure: 10 bar. Max. differential pressure: 1 bar. Connection: G1 thread with flat gasket. Thermostatic valve body: Brass. Dimensions: B = 44 mm, C = 73.5 mm, E = 27 mm, L = 529 mm.