Used in underfloor heating/cooling systems as well as radiator heating systems. Distributes the heating medium to the underfloor heating loops and to radiators, and the cooled medium in the case of underfloor cooling. Includes: – 1 supply manifold with balancing valves – 1 return manifold with thermostatic valves with electric control option (thermoelectric head/actuator) – 2 brackets for the manifold set. The balancing valve is a flow and pressure-drop balancing valve according to the project specifications. To ensure correct operation, please observe the flow direction. For flow indication, a PexKIT 3/4″ flow meter (0.5–2.4 L/min), Valrom code 64199000025, can be installed on the return (return manifold with thermostatic valves) on each circuit. Max. differential pressure: 0.8 bar Max. working pressure: 10 bar Max. working temperature: 90°C Max. ambient temperature: 50°C Dimensional characteristics: H = 288 mm L = 50 mm S = 25 mm h1 = 54 mm W = 210 mm P = 77 mm Ltot = 287 mm L = 262 mm.